VPD Calculator for Cannabis
Enter your air temperature and humidity in Fahrenheit or Celsius and get the leaf VPD, the dew point and the humidity your growth stage needs. It checks your room against the temperature, humidity and VPD bands from our VPD chart guide, warns you when the humidity is a mold risk even if the VPD looks fine, and tells you what lights-off will do to the numbers.
Leaf VPD 1.22 kPa
Checks for this stage
To land in the middle of the band
At lights-off
Drying flower? Do not use VPD for that. Our drying guide runs a humidity schedule instead, because dead tissue has no stomata to protect.
Your VPD chart
Rows are air temperature, columns are relative humidity, and each cell is leaf VPD in kPa.
Our VPD chart guide also has a ready-made chart in Fahrenheit and Celsius with the stage bands drawn in.
VPD, temperature and humidity targets by stage
| Stage | Air temperature | Relative humidity | Leaf VPD |
|---|---|---|---|
| Seedlings and fresh clones | 72 to 78°F (22 to 26°C) | 70 to 80% | 0.4 to 0.8 kPa |
| Vegetative | 71 to 82°F (22 to 28°C) | 55 to 65% | 0.8 to 1.2 kPa |
| Flower, weeks 1 to 3 | 70 to 80°F (21 to 27°C) | 55 to 65% | 0.9 to 1.1 kPa |
| Flower, weeks 4 to 6 | 70 to 80°F (21 to 27°C) | 50 to 60% | 1.1 to 1.3 kPa |
| Late flower, week 7 to harvest | 65 to 75°F (18 to 24°C) | 45 to 55% | 1.1 to 1.3 kPa |
If you only remember one band, remember 1.0 to 1.2 kPa. It overlaps the band for veg and for every week of flower. The reasons behind each number are in our VPD chart guide, and the humidity bands come from our indoor growing guide and our flowering stage guide.
How the calculator works
VPD is how much more water vapor the air could hold than it does, measured at the leaf. It is worked out in three steps, all with the saturation vapor pressure equation from the United Nations Food and Agriculture Organization's Irrigation and Drainage Paper 561: es = 0.6108 x exp[17.27 x T / (T + 237.3)], with T in Celsius and es in kPa.
| What | How it is worked out |
|---|---|
| Actual vapor pressure of the air | es at the air temperature x relative humidity / 100 |
| Leaf VPD | es at the leaf temperature, minus the actual vapor pressure of the air |
| Air VPD | es at the air temperature, minus the actual vapor pressure of the air |
| Dew point | The temperature where es equals the actual vapor pressure of the air |
| Absolute humidity | 2,167 x actual vapor pressure in kPa / (air temperature in Celsius + 273.15), in grams per cubic meter |
| Lights-off humidity | The same actual vapor pressure, divided by es at the lights-off temperature, assuming no water is added or removed |
The one guess in all of this is the leaf temperature. A healthy, well-watered leaf usually sits within about 2°C (3.6°F) of the air, under LED, HPS or the sun2, so we assume it runs 2°F (about 1°C) cooler, the same assumption our printed chart makes. A leaf that is short of water cannot cool itself and can run far hotter than the air. That is why the most useful thing you can do with this calculator is pick "I measured it" and enter the reading from an infrared thermometer pointed at a healthy fan leaf in the middle of the canopy, lights on. At 77°F (25°C) and 55% humidity, a leaf 4°F (2°C) cooler than the air reads 1.03 kPa and one 4°F (2°C) warmer reads 1.87 kPa, in the same room. Our guide covers why the leaf matters more than the lamp.
When the humidity matters more than the VPD
Bud rot and powdery mildew respond to relative humidity and free water, not to VPD3. A tent at 80°F (27°C) and 62% humidity and one at 70°F (21°C) and 50% read almost the same VPD, and they are not the same room to a mold spore inside a dense cola. So in late flower, when the humidity band and the VPD band disagree, humidity wins: hold the humidity band, take the cool end of the temperature range, and let the VPD read high. The calculator flags that case for you. Our bud rot guide and powdery mildew guide cover the reasoning, and our grow tent humidity guide covers how to bring humidity down.
The same air holds more humidity as it cools, which is why the lights-off check is there. Air at 77°F (25°C) and 50% humidity that cools to 67°F (19°C) reads about 70% with no water added. Run your exhaust and dehumidifier on a humidity setpoint through lights-off, never on a timer. Our grow tent temperature guide covers the lights-off drop.
Frequently asked questions
What is a good VPD for cannabis?
Between 0.8 and 1.3 kPa covers veg and every week of flower. If you want one number to hold from the start of veg to the day before harvest, use 1.0 to 1.2 kPa, which overlaps every stage's band. Seedlings and fresh clones want a gentler 0.4 to 0.8 kPa, which is what a propagation dome gives you.
What is the difference between leaf VPD and air VPD?
Air VPD treats the leaf as if it were the same temperature as the air, which is what most hygrometers and controllers show. Leaf VPD uses the leaf's own temperature, which is what the plant actually feels. With a leaf 2°F (about 1°C) cooler than the air, leaf VPD reads about 0.2 kPa lower than air VPD at normal room temperatures.
Should I use Fahrenheit or Celsius?
Either. The calculator converts everything to Celsius for the math and gives the same VPD in both. Switching units also converts the numbers you have already entered.
What leaf temperature should I enter?
The real one, if you can. Point an infrared thermometer at a healthy fan leaf in the middle of the canopy with the lights on. If you do not have one, keep our default of 2°F (about 1°C) below the air. If the leaf reads several degrees above the air, stop adjusting humidity and check the roots and the watering first: a hot leaf usually means the plant is not drinking.
Is 1.6 kPa too high?
For cannabis in veg or flower, it is higher than you want. Most charts treat about 1.6 kPa as the point where a plant starts closing its stomata to save water, though nobody has measured that threshold on cannabis. Before you fix the room, check the leaf: a reading that high with a hot leaf is usually a root zone problem.
- Allen, R. G., Pereira, L. S., Raes, D., & Smith, M. (1998). Crop evapotranspiration: guidelines for computing crop water requirements. FAO Irrigation and Drainage Paper 56, Chapter 3. Food and Agriculture Organization of the United Nations. https://www.fao.org/4/x0490e/x0490e07.htm
- Nelson, J. A., & Bugbee, B. (2015). Analysis of environmental effects on leaf temperature under sunlight, high pressure sodium and light emitting diodes. PLoS ONE, 10(10), e0138930. https://doi.org/10.1371/journal.pone.0138930
- Punja, Z. K. (2021). Emerging diseases of Cannabis sativa and sustainable management. Pest Management Science, 77(9), 3857-3870. https://doi.org/10.1002/ps.6307